| Organization: | Alberta Precision Laboratories | ||||||||||
| Message Alert: | PLEASE NOTE: This Test Directory is in an interim state and due to changes pertaining to the DynaLIFE transition, performing site for routing has not been updated. Please refer to Laboratory Information System for appropriate routing. | ||||||||||
| Test Name/Synonym: | Erythrocyte Sedimentation Rate (Synonym: ESR) | ||||||||||
| Ordering Alert: | In most cases, C-Reactive Protein (CRP) is the preferred test over ESR. AHS Memo C – Reactive Protein (CRP) Substitution for Erythrocyte Sedimentation Rate (ESR) For 3rd party client testing the clinical criteria does not apply. CRP should not be substituted for ESR testing in these cases. | ||||||||||
| LABID (Connect Care): | LAB322 | ||||||||||
| Specimen Type: | Blood | ||||||||||
| Specimen Source: | Venous, Arterial, Central Line | ||||||||||
| Primary Container: |
| ||||||||||
| Alternate Containers: | LAVENDER EDTA | ||||||||||
| Minimum Collection Volume: | Calgary, and Edmonton Zones, St. Theresa General Hospital (FVH), Northwest HC (HLH), and Northern Lights Regional HC (FMH): 1.36 mL Central, South and North Zone sites - EXCEPT St. Theresa General Hospital (FVH), Northwest HC (HLH), and Northern Lights Regional HC (FMH) 1.6 mL | ||||||||||
| Specimen Collection Requirements: | Calgary, and Edmonton Zone, St. Theresa General Hospital (FVH), Northwest HC (HLH), and Northern Lights Regional HC (FMH): The 1.36 mL BLACK-CITRATE (EXCYTE®) ESR tube is used for ESR testing ONLY.
Central, South and North Zone sites - EXCEPT St. Theresa General Hospital (FVH), Northwest HC (HLH), and Northern Lights Regional HC (FMH):
| ||||||||||
| Test Resources: |
| ||||||||||
| Stability and Storage: |
| ||||||||||
| Processing: | DO NOT centrifuge. Do not remove cap from the tube as this is a closed system test. | ||||||||||
| Testing Schedule: | Daily | ||||||||||
| Reference Interval: |
| ||||||||||
| Testing Area: | Hematology | ||||||||||
| Performing Site: |
| ||||||||||
| Additional Test Information: | ESRs are unreliable in anemia, leading to false increases. For sites that perform CRP testing, ESR order will be substituted with a CRP if clinical indications are not met. This does not apply to 3rd party client testing.
| ||||||||||
| Contact Comments: | 1-877-868-6848 | ||||||||||
| Last Updated On: | Tuesday, August 20, 2024 | ||||||||||
| Registered Trademark Comments: | EXCYTE® is a registered trademark of ELITechGroup IMPROVACUTER® is a registered trademark of Guangzhou Improve Medical Instruments Co., Ltd. | ||||||||||