--- Query Results --- | |||||||||||
Organization: | Alberta Precision Laboratories | ||||||||||
Message Alert: | PLEASE NOTE: This Test Directory is in an interim state and due to changes pertaining to the DynaLIFE transition, performing site for routing has not been updated. Please refer to Laboratory Information System for appropriate routing. | ||||||||||
Test Name/Synonym: | Cell Count, CRRT Effluent (Synonym: CELLCNT, CELL COUNT, CRRT EFFLUENT, Continuous Renal Replacement Therapy, Prisma, hemodialysis, haemodialysis) | ||||||||||
Test Includes: | Color, clarity and RBC count | ||||||||||
LABID (Connect Care): | LAB7209 | ||||||||||
Specimen Type: | Other | ||||||||||
Specimen Source: | Other | ||||||||||
Primary Container: | LAVENDER EDTA | ||||||||||
Alternate Containers: | STERILE CONTAINER | ||||||||||
Minimum Collection Volume: | 1 mL | ||||||||||
Specimen Collection Requirements: | DO NOT send large volumes of fluid. Specimen MUST NOT be clotted | ||||||||||
Test Resources: | Indicate test under Sterile Body Fluid Section
| ||||||||||
Stability and Storage: | Fluid specimens must be transported for processing as soon as possible. Cellular elements may deteriorate upon standing. | ||||||||||
Processing: | Place 3-4 mL of fluid into Lavender EDTA tube immediately following collection. Mix well by inverting tube 6-8 times. Send immediately to the laboratory. | ||||||||||
Testing Schedule: | Daily | ||||||||||
Reference Interval: | No reference ranges will be reported | ||||||||||
Testing Area: | Hematolgy | ||||||||||
Performing Site: |
| ||||||||||
Additional Test Information: | Continuous Renal Replacement Therapy (CRRT) Effluent is not technically a body fluid, but rather a combination of artificial dialysate fluid and filtered plasma constituents. This test name is used to distinguish effluent samples from true body fluid samples assessed under the “Cell Count, Body Fluid” test. | ||||||||||
Contact Comments: | 1-877-868-6848 | ||||||||||
Last Updated On: | Friday, November 3, 2023 |